
Cardiac Electrophysiology Without Fluoroscopy
- Publisher's listprice EUR 117.69
-
The price is estimated because at the time of ordering we do not know what conversion rates will apply to HUF / product currency when the book arrives. In case HUF is weaker, the price increases slightly, in case HUF is stronger, the price goes lower slightly.
- Discount 20% (cc. 9 985 Ft off)
- Discounted price 39 939 Ft (38 037 Ft + 5% VAT)
49 924 Ft
Availability
Estimated delivery time: In stock at the publisher, but not at Prospero's office. Delivery time approx. 3-5 weeks.
Not in stock at Prospero.
Why don't you give exact delivery time?
Delivery time is estimated on our previous experiences. We give estimations only, because we order from outside Hungary, and the delivery time mainly depends on how quickly the publisher supplies the book. Faster or slower deliveries both happen, but we do our best to supply as quickly as possible.
Product details:
- Edition number 1st ed. 2019
- Publisher Springer
- Date of Publication 15 August 2020
- Number of Volumes 1 pieces, Book
- ISBN 9783030169947
- Binding Paperback
- No. of pages245 pages
- Size 254x178 mm
- Weight 591 g
- Language English
- Illustrations 2 Illustrations, black & white; 85 Illustrations, color 129
Categories
Short description:
This book reflects how the concern regarding the effects of radiation exposure in patients and health personnel involved in cardiac electrophysiology (EP) has inspired new developments in cardiac electrophysiology procedures without the use of fluoroscopy. This innovative method has become a subspecialty within electrophysioloy with several EP laboratories around the world adopting an exclusive non-fluoroscopy approach. It features guidance on how to use three dimensional (3D) navigation systems, ablation energy sources and zero-fluorospic implantation of cardiac electronic devices. The potential complications and associated preventative methods with utilising RFCA are also described.
Cardiac Electrophysiology Without Fluoroscopy offers a thorough description of the technique correlated to the performance of EP procedure without the use of radiation, and provides a valuable resource for those seeking a practically applicable guide on how to perform cardiacEP without fluoroscopy, including practising and trainee electrophysiologists, cardiac imagers, general cardiologists and emergency medicine physicians.
Long description:
This book reflects how the concern regarding the effects of radiation exposure in patients and health personnel involved in cardiac electrophysiology (EP) has inspired new developments in cardiac electrophysiology procedures without the use of fluoroscopy. This innovative method has become a subspecialty within electrophysioloy with several EP laboratories around the world adopting an exclusive non-fluoroscopy approach. It features guidance on how to use three dimensional (3D) navigation systems, ablation energy sources and zero-fluorospic implantation of cardiac electronic devices. The potential complications and associated preventative methods with utilising RFCA are also described.
Cardiac Electrophysiology Without Fluoroscopy offers a thorough description of the technique correlated to the performance of EP procedure without the use of radiation, and provides a valuable resource for those seeking a practically applicable guide on how to perform cardiac EP without fluoroscopy, including practising and trainee electrophysiologists, cardiac imagers, general cardiologists and emergency medicine physicians.
MoreTable of Contents:
Clinical Studies of a purely 3D Navigation in Interventional Managements of Tachyarrhythmia.- Radiation exposure and safety for the electrophysiologist.- Ablation Energy Sources-Principles and Utility in Ablation without Fluoroscopy.- 3D mapping and reduction in radiation exposure.- Catheter Placement and Model reconstruction.- Learning curve for zero-fluoroscopic procedure.- Atrioventricular Nodal Reentrant Tachycardia (AVNRT) with zero-fluoroscopic procedure.- AV Nodal re-entrant tachycardia ablation without fluoroscopy.- Non-Fluoroscopic Catheter Ablation of Accessory Pathways.- Focal atrial tachycardia.- Ablation of atrial flutter with zero fluoroscopy approach.- Non-Fluoroscopic Catheter Ablation of Atrial Fibrillation.- Non-Fluoroscopic Catheter Ablation of Idiopathic Ventricular Arrhythmias.- Ventricular Tachycardia with Structural Heart Disease.- Reduction on radiation exposure in pediatric population undergoing ablation procedures.- Complications of RFCA and Prevention Method.- Safety of zero-fluroscopic procedure during pregnancy.- Cost optimization when using 3-D mapping systems for a non fluoro EP lab.- Zero-fluoroscopic implantation of cardiac electronic Device.- Cardiac Resynchronization Therapy (CRT) guided by 3D mapping system.- Transesophageal Electrophysiological Study without fluoroscopy.
More
Cardiac Electrophysiology Without Fluoroscopy
Subcribe now and receive a favourable price.
Subscribe
49 924 HUF